Universitas Yos SoedarsoJurnal Ilmiah
01a1c633-22f0-7597-aa09-0f9a7577b825 Civil Engineering JournalVol. 7 No. 1 (2025) · e-ISSN 2685-7707

ARTIKEL PENELITIAN · Vol. 7 No. 1 (2025)

Analisis Retak Struktur Beton Dengan UPV Proyek Civil Work-01 ITS Surabaya

Analisis Retak Struktur Beton Dengan UPV Proyek Civil Work-01 ITS Surabaya

  1. Program Studi Teknik Sipil, Fakultas Teknik, Universitas Yos Soedarso Surabaya, Indonesia

Abstrak

Kerusakan struktural pada beton, seperti retakan, sering kali sulit dideteksi secara visual karena banyak terjadi di bagian dalam struktur. Penelitian ini bertujuan untuk mengidentifikasi dan menganalisis retakan pada struktur beton menggunakan metode Ultrasonic Pulse Velocity (UPV) di Proyek Civil Work-01 ITS Surabaya. Obyek penelitian adalah elemen beton yang retak pada beberapa lantai bangunan, dengan metode penelitian untuk mendeteksi kedalaman retak melalui nilai kecepatan rambat gelombang ultrasonik pada titik-Data diperoleh dari pengukuran langsung di lapangan, kemudian dianalisis untuk mengetahui hubungan antara kecepatan rambat gelombang dan kondisi beton. Hasil analisis menunjukkan adanya variasi nilai kecepatan pada tiap titik pengujian. Nilai yang rendah mengindikasikan adanya penurunan mutu beton atau keberadaan retakan internal. Sebagian besar retakan ditemukan pada area sambungan dan bagian yang menerima beban tinggi. Secara keseluruhan, retak-retak yang terjadi masih dalam toleransi dan tidak mempengaruhi stabilitas struktur.

Abstract

Structural damage in concrete, such as cracking, is often difficult to detect visually because it frequently occurs within the interior of the structure. This study aims to identify and analyze cracks in concrete structures using the Ultrasonic Pulse Velocity (UPV) method on the Civil Work-01 ITS Surabaya Project. The research object is cracked concrete elements located on several floors of the building. The research method involves detecting crack depth through ultrasonic pulse velocity values at specific points. Data were obtained from direct on-site measurements and subsequently analyzed to determine the relationship between pulse velocity and concrete condition. The analysis results show variations in pulse velocity values at each test point. Lower values indicate a decrease in concrete quality or the presence of internal cracks. Most cracks were found in joint areas and in sections subjected to high loads. Overall, the observed cracks are still within tolerance limits and do not affect the structural stability.

Cara mengutip

Mochammad Irwan Hariyono, Eva Sundari, & Muhammad Alfiansyah Risyanto (2025). Analisis Retak Struktur Beton Dengan UPV Proyek Civil Work-01 ITS Surabaya. Civil Engineering Journal, 7(1), 1-4.